pxi-5402. I am looking for a pxi card to generate 3 channels analog outputs. pxi-5402

 
I am looking for a pxi card to generate 3 channels analog outputspxi-5402

Hardware Product Lifecycle Policies. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. 1 V pk-pk to 20 V pk-pk into 1 MΩ BNC Tee (m-f-f) Pasternack PE9174 Verifications: • AC amplitude accuracy Impedance: 50 Ω Double banana plug to BNC (f) Pasternack. The chassis includes an AUTO/HIGH fan-speed selector to optimize cooling and acoustics. 20 mhz带宽,单通道,14位pxi波形发生器—pxi-5402是一款20 mhz函数发生器,能够生成正弦波、方波、三角波和斜波等标准函数以及伪随机噪声和直流信号等其他信号。函数发生器可以生成-5 v~+ 5 v的信号,并使用直接数字合成(dds)技术精确生成波形。From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. REF IN Input Accepts a PLL Reference clock from an external source and can frequency lock the Sample clock timebase to the external Reference clock. PXI. QQ: 3007273135. You can request repair, schedule calibration, or get technical support. Manufacturer: National Instruments. RoHS. 1 When the USB Screw Terminal device is powered on, the analog output signal is not defined until after USB configuration is complete. The PCI-5402 features the direct digital synthesis (DSS) method for signal generation. What do we need (SW & HW) to calibrate the PXI modules such as PXI4070, PXI4060, PXI 5402, PXI4110 and other instrument using METCAL if possible? Thanks & Regards. . Buy Now. 1 MXI Express and MXI-4 are supported on Windows 10/8. Pickering Interfaces designs and manufactures modular signal switching and simulation for use in electronic test and verification. PXI-5402. No damage occurs if the CH 0 output is shorted to. com Note Unless manually disabled, NI-FGEN automati cally loads with the operating system and enables the device. A comprehensive collection of workers compensation information, including underwriting, data, and reference manuals. × 8. The parameters space of the optimization problem concern the voltage amplitude, the burst frequency and the duty-cycle (Figure 3). (B) Cell rotation around an axis perpen-dicular to the optical axis, which is essential for isotropic 3D image reconstruction. When trying to install & run a PXI-5402 Sig Gen installed in a 1033 chassis, with Max it does not respond and after 10 secs or so gives the errorThis example shows how to initialize the Ag3446x IVI-C driver, read a few properties of the driver, measure AC voltage using Keysight® Technologies 34460A digital multimeter, and output the result in MATLAB®. 1 Vpk-pk to 20 Vpk-pk into 1 MΩ • Frequency: 50 kHz SMB (plug) to BNC (f) adapter Fairview Microwave SM3633 Verifications: • Timebase accuracy • DC accuracy. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. This file contains installation instructions and compatibility information for InstrumentStudio 2022 Q4. The NI PXI-5402 (Part Number: 779655-01, 192887E-01L) is a 20 MHz Waveform Generator fit for producing standard functions including sine, square, triangle, ramp, and different signals like psuedorandom noise. The circuitry has several resistors and a step down transformer in the path. PXI is a product of National Instruments (NI),. 001 degrees -Waveform memory:32 MSamples per channel -Waveform sequencing steps:Up to 65,535Shop National Instruments PXI. Re: What is needed to calibrate PXI modules using METCAL? Nick_F1. If your PC is unable to see your modules associated with your PXI chassis, try shutting down and then repowering your PC while your NI Chassis is connected and powered on with its associated modules connected. PXI Chassis. You can also use InstrumentStudio 2018 to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. PXI-5402 functional generator. NI PXI-5402/5406, Keysight 33220A, or Keysight 33500B Verifications: • AC amplitude accuracy Sine wave generation: • Amplitude: – 0. 942,90. Used. Waveform summing. Глава: SYNC OUT/PFI 0 and PFI 1. The NI PCI-5402 is used in applications where fast analog signal generation is required. Systems Engineering Software. The PXIe-5160 is a 500 MHz , 10-bit oscilloscope with a sample rate of up to 2. vi (see attached) using an NI PXIe-1073 + NI PXI-5402 + NI PXI-5122 and LabVIEW 2013. The PXIe-1088 features an all-hybrid backplane to meet a wide range of high-performance test and measurement application needs. vi ‏459 KB. Added support for arbitrary waveform generation mode to the Waveform Generator panels. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. This document lists specifications for the NI PXI/PCI-5402/5406 (NI 5402/5406) arbitrary function generator. As it is a A PXI-5412 would be better suited to this task. Power down the computer, then the PXI (e) chassis. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. used. Download All 0 Kudos Message 1 of 4 (405 Views) Reply. 0 cm × 13. The PXIe-5160 is a 500 MHz , 10-bit oscilloscope with a sample rate of up to 2. NI software installs VC2015 Runtime and . Hi - I am trying the Stimulus_Response_Example. Control NI-FGEN devices and create your own arbitrary waveforms using MATLAB. NI. You can also use InstrumentStudio to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. 125 Vpk-pk to 2. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. National Instruments repair services by Trescal. The same chassis carrying the PXI-6281 also houses a function generator (National Instruments: Model PXI-5402). Downloadable Technical Manuals and Datasheets. Updated 2023-02-21. To see this PDF, click the link to view the requested file: 371707e. NI PXI-5402 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz. NI InstrumentStudio 2022 Q3 Readme. Basic. 哪个是PXI硬件合适的设备驱动程序?. NI PXI-6259 16-Bit, 1 MS/s (Multichannel), 1. Trust Trescal to repair your National Instruments equipment no matter where you are. Continuous Trigger Mode. Solved! Go to Solution. NI PXI-5402 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz. Part Number: 192887B-01, 192887C-01,. If the PLL. skype:628652ed16045b6e The National Instruments PXI-5402 / PXI-5406 14/16-bit 20/40 MHz Arbitrary Function Generator devices are 100 MS/s, 40 and 20 MHz arbitrary function generators (AFGs) that feature up to 16 bits of resolution and 32 kB of onboard memory for arbitrary function generation in a compact, 1-slot 3U PXI module or PCI board. Phase adjustment. DAK Assembly - MAC Panel Company. 0 but I believe it said there was either a patch/service pack or newer version available. Windows Embedded Standard 7 (SP1) Windows Server 2008 R2 (SP1) 64-bit. The voltage signals were amplified by 100× using a Stanford. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. NI PXI-5402 New AUTOMATION Controller MODULE DCS PLC Module. NI Product Documentation Center. 1 V pk-pk to 3. System Ltd, A-303). Perspectives. The circuitry has several resistors and a step down transformer in the path. It was damaged, so I removed it to send for repair. Depending on the user’s signal and application needs, they can choose up to a 4X advanced addition for a viable testing rate up to 400. Please select your country. Complies with the essential requirements of the following applicable UK Regulations: Electromagnetic Compatibility (EMC) Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic. This calibration. NI PXI-5402/5406. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDF Product Support Resources. Try searching for what you need. The NI PXI-1031 4-slot 3U Chassis ships with Free Ground and a 1-3 Year Warranty, based on New, Reconditioned, Used, or Repair Condition of the model. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. produced by a generator card (PXI-5402), this low voltage being amplified with a scale factor of 3/3000 V (Trek 30/40) before supplying the top electrode. ni pxi/pci-5402/5406 仕様 14/16 ビット20/40 mhz 任意関数発生器 このドキュメントには、ni pxi/pci-5402/5406(ni 5402/5406)の任意 関数発生器の仕様が記載されています。特に注記のない限り、各仕様にお いて以下の条件が適用されます。 • アナログフィルタ有効化。To perform the NLEIS measurements, a Solartron 1287 potentiostat was connected through a GBIP port to a National Instrument PXI-1036 chassis system, which contains a PXI-8331 controller, a PXI-5402 function generator and a PXI-5922 digitizer. The best replacement for this device will be a PXI, PXIe, or CompactDAQ chassis that is capable of housing all required PXI or C Series I/O modules. Connecting to PXI-5402 instrumentation is easy with SCOUT. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. Ethernet module, motion control module, analog input module, analog output module, digital input module, digital output. Oglejte si zgodovino naročil. procedure is intended for. $3,290. 0 the latest FGEN driver?I have a PXI-5402 function generator running in a PXI-1031 chassis. QQ: 3007273135. This document contains instructions for writing a calibration procedure for. hwdb | 2 3 files changed, 2199 insertions(+), 39 deletions(-) New. † (PXI) Ensure that the PXI chassis fan speed is set to HI, that the filter fans are clean, and that the empty slots contain filler panels. 1 V pk-pk to 20 V pk-pk into 1 MΩ BNC Tee (m-f-f) Pasternack PE9174 Verifications: • AC amplitude accuracy Impedance: 50 Ω Double banana plug to BNC (f) Pasternack. The NI 5406 is a 40 MHz bandwidth, 16-bit arbitrary function generator. 我的PXI-5402不允许我使用Labview中的NIFGEN Arbitrary Function Generator Express VI。它报出“设备未发现”的错误。该卡在FGEN SOFT FRONT PANEL. PXI Express System Timing Slot 5. Giving our customers choice means supplying test equipment and solutions across a range of relevant industries and sectors. Software. しかし、1つの波形だけであれば、ユーザー定義の波形を出力することができます。. For moreThis example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. Fax: (240) 376-1381. Optional Items • PXI Chassis Slot Blocker kit (NI part number 199198-01) • SMA (m)-to-SMA (m) cables • SMA (m)-to-MMPX (m) cables • MMPX (m)-to-MMPX (m) cables • OCuLink x4, 1 m. . RoHS. Since simulation mode is enabled, the resource name can be specified as empty. With PXI-5402 it's a simple task using standard waveform settings but with PXIe-5413 probably I have to move to arbitrary. The PXI-5422 is available to be calibrated. The instruments are from left to right function generator NI PXI‐5402, dualchannel oscilloscope NI PXI‐5112, DC power supplyNI PXI‐4110 with APS‐4100, and DMM NI PXI‐4070. Chassis Mounting Kit for 40-924, 60-102C & 60-102D. If not,. NI 5402的任意波形输出. Power on the computer and install the compatible version of PXI Platform Services. PXI-5402 PXIe-6363 PXI-6289 PCI-781XR PXI-5105 PCI-1428 PCIe-6259 NI-9012 USB-6251 PXI-2520 PXIE-6674T PCI-4454 PXI-4472 PXI-5142 PXIe-8133 SWB. Connector blocks; NI 5402/5406. Place the module edges into the module guides at the top and bottom of the chassis. dev = NIFGEN with properties: Model: "NI PXI. The The Power of Choice. Page 10 Refer to Figure 1 for the names and locations of the NI 5402/5406 front panel connectors. May be pxi 6711 can be sufficient. Reference sourceThe DMF system includes an AC power amplifier (A303, A. I have also installed FGEN, with it's associated drivers. dev = NIFGEN with properties: Model: "NI PXI. This is a hybrid-slot compatible PXI module that can be used in both PXI Express hybrid slots and standard PXI slots. Devices such as NI PXI-5402, 5406, 5441, 5442, 5450 or 5451 supports phase continuous frequency. the LS-9501 is sent to a NI PXI-4472B 102. , Ltd. The PXI-1050 is a combination PXI and SCXI chassis with 8 PXI slots and 4 SCXI slots. Select Page. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS). . 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator —The PXI‑5402 is a 20 MHz function generator capable of generating standard. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. National Instruments PXI-5402 14-Bit 20 MHz Arbitrary Function Generator This is a hybrid-slot compatible PXI module that can be used in both PXI Express hybrid slots and standard PXI slots. In the present investigation thePlease update the metadescription to: Project Integration LLC created an automated test system to measure the parameters of high-power IGBT and MOSFET transistors with an intuitive user interface. This example shows how to initialize the Ag3446x IVI-C driver, read a few properties of the driver, measure AC voltage using Keysight® Technologies 34460A digital multimeter, and output the result in MATLAB®. E-Mail:2322181769@qq. It accepts PXI Express modules in every slot and supports standard PXI hybrid. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. Waveform Generator, PXI-5402, 1 Channel, 40. Cannot find the driver — If you find your device under Other Devices with a yellow question mark on it, and the properties show error: Code 1: Device not configured correctly. PXIe, 8-Slot (4 Hybrid Slots, 2 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 8 GB/s PXI Chassis —The PXIe‑1082 features a high-bandwidth backplane to meet a wide range of high-performance test and measurement application needs. Drives / Motion / Motor Control / Positioning. Response: Dear PTherm, I'm going to assume that you're asking about the maximum frequency of the clocks which come in each product, not the maximum sampling rate that's possible with each product (these two aren't necessarily the same). These devices have four BNC connectors, as shown. Note: Ensure your PXI(e) target, LabVIEW, Real Time module and Device Drivers are compatible with selected software version. NI TestStand Software. I would appreciate any ideas / suggestions. † (PXI) Ensure that the PXI chassis fan speed is set to HI, that the filter fans are clean, and that the empty slots contain filler panels. All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon. NI PXI-5402 14-bit, 100 MS/s Function Generator, 20 MHz Sine/Square; NI PXI-4110 Triple Output DC Power Supply with APS-4100 Aux Power; NI PXIe-5122, 2-ch, 100 MS/s Digitizer w/256 MB/ch Onboard Memory; Luna Hyperscan - High resolution and sensitivity multiple fiber optic strain provides diagnostic capability of structures and materials. I have used MAX, and the generator itself is working fine. I have a PXI-5402 function generator that I have set up to generate a single pulse of a square weave using the frequency list method, and can very that pulse width from 10-1000mS as desired. Popular PXI Series Include: NI. Waveform Generator, PXI-5402, 1 Channel, 40 MHz. 5 Vpk-pk into 50 Ω – 0. Return to Home Page; Toggle navigation; Solutions. The NI 5114 is a 2-channel, 125 MHz oscilloscope. PXI Vector Signal Transceiver, 6 GHz, 1 GHz Bandwidth. They were actuated using a 1 kHz AC signal that was produced by an NI PXI-5402 signal generator and amplified to 200 V rms using a Trek PZD700A amplifier. hi. Power on the computer and reset the MAX database. Different orders of differentiation lead to. The PCI-5402 features the direct digital synthesis (DSS) method for signal generation. 20 MHz Bandwidth, 14-Bit Waveform Generator Device —The PCI‑5402 can generate standard functions, including sine, square, triangle, and ramp as well as other signals like pseudorandom noise and DC signals. Front Panel Connectors. InstrumentStudio 2021 has the following requirements: Pentium 4 G1 equivalent or later (Intel i5 equivalent or higher recommended) 1024 x 768 screen resolution (1366 x 768 or higher recommended) InstrumentStudio 2021 supports the following operating systems: Windows Server 2016 64-bit. For moreThis example shows how to initialize the Ag3446x IVI-C driver, read a few properties of the driver, measure AC voltage using Keysight® Technologies 34460A digital multimeter, and output the result in MATLAB®. An image of the experimental facility and a representative image showing a droplet and measured contact angles is shown in supplemental figure, Fig. Configuring the RT Target: After you install all the required software on the host computer, use Measurement & Automation Explorer (NI-MAX) to configure the general. Waveform Generator, PXI-5402, 1. Outputs of multiple PXI-5402 signal generators can be connected together. Added support for exporting instrument events to PXI chassis trigger lines. 1 V pk-pk to 20 V into 1 MΩ • Frequency: 50 kHz SMB (plug) to BNC (f) adapter Fairview Microwave SM3633 Verifications: • Timebase accuracy • DC accuracy. NI PXI Platform Services is already included as part of NI instrument drivers, but there may be cases where only the PXI Platform Services software is needed for certain applications, such as using NI MXI products or using NI PXI or PXI Express chassis without installing other NI PXI hardware drivers. NI USB-6259 BNC Front Panel and Pinout. High-Performance Test. Giving our customers choice means supplying test equipment and solutions across a range of relevant industries and sectors. The developed ATE system measures the following parameters:NI 5402/5406 Calibration Procedure 6 ni. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. NI PXI-5402/5406 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz Sine wave amplitude: • 0. ) or go to. Ta izdelek ste že kupili. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS). Multimeters Specifications National Instruments PXI-4071 7. They offer various configurations and features, such as high current, high voltage, and high density. NI PXI/PCI-5402/5406 The NI 5402 is a 20 MHz bandwidth,14-bit arbitrary function generator. Features: Phase-Continuous Frequency Hopping and Frequency Sweeps. Knowledgebase. To see this PDF, click the link to view the requested file: 372135a. But now I'm trying to take an example for Visual Studio provided with FGEN and modify it to operate the PXI-5402 program. The signals generated by the PXI-5402 Function Generator are amplified by this system for our high-voltage actuated experiments. the NI PCI/PXI-5402/5406 arbitrary function generators. This function generator can generate signals from -5 V to +5 V and uses direct digital. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 NI PXI-5402/5406 or Agilent 33220A Verifications: • AC amplitude accuracy Sine wave frequency: 50 kHz Sine wave amplitude: • 0. NI 5402/5406 Calibration Procedure 6 ni. Lab System Ltd. • Ensure that the PXI chassis fan speed is set to HIGH, that the fan filters (if present) are clean, and that the empty slots contain slot blockers and filler panels. $8,280 USD. PXI Controller. NI PXI-6259 16-Bit, 1 MS/s (Multichannel), 1. A LabView program is used to control the relays and electrodes. So could I. Optional Items • PXI Chassis Slot Blocker kit (NI part number 199198-01) • SMA (m)-to-SMA (m) cables • SMA (m)-to-MMPX (m) cables • MMPX (m)-to-MMPX (m) cables • OCuLink x4, 1 m. M. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS). Options. Waveform Generator Device, PCI-5402, 1 Channel, 20 MHz Sine/Square, 1 MHz Triangle/Ramp. Unfortunately I discovered that the DC offset for this last is only 50% of amplitude despite a more wide range of the PXI-5402: I'm really surprised because it's a big limitation. . vi (see attached) using an NI PXIe-1073 + NI PXI-5402 + NI PXI-5122 and LabVIEW 2013. It is fitted with three 55cfm fans to ensure efficient cooling of the chassis and modules. On your PC open Services and confirm that NI PXI Chassis Management and NI PXI Resource Manager services are running. ) for signal exchange. . 1 Vpk-pk to 5. NI™ manufactures arbitrary waveform and function generators that use the NI-FGEN driver. Unless otherwise noted, the following conditions were used for each. These devices have four BNC connectors, as shown. I have tested both the NI PXI-5402 and the NI PXI-5122 using the NI MAX Self-Test and both have passed them and both are working properly. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 125 Vpk-pk to 20 Vpk-pk into 1 MΩ • Frequency: 50 kHz BNC Tee (m-f-f) Pasternack PE9174 Verifications: • AC amplitude accuracy Impedance: 50 Ω Double banana plug to BNC (f. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS). Waveform Generator, PXI-5402, 1 Channel, 40 MHz. 我們實驗室買了PXIE-5622、PXIE-5601(RFSA)、PXI-5652(RFSG)、PXI-5402(FGEN)模組以及PXIE-8106控制器、PXIE-106Q機箱,我不知道它們能做什麼,主要是PXIE-5601(RFSA)和PXI-5652(RFSG)我真的不知道它們功用, Return to Home Page; Toggle navigation; Solutions. PXI-1052: PXIe-1075: cDAQ 9178 cDAQ 9189 cDAQ 9179 NI PXI-5102 (scope) 2. National Instruments PXI-5402 14-Bit 20 MHz Arbitrary Function Generator. Waveform Generator 1 Channel PXI-5402 20MHz 3 Years 779657-01 3958561 Data Sheet. . The NI PXI-5402/5406 is intended for indoor use only. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator. com Note Unless manually disabled, NI-FGEN automati cally loads with the operating system and enables the device. 1/7 support for the PXI-5404 does not include support for external. Burst/Stepped; Single Trigger Mode; Continuous Trigger Mode; Phase-Locked Loops and Module Synchronization; Specifications; Calibration; Accessories. It is also shielded. + 2. Un ejemplo completo esta adjunto en este Documento de Soporte en formato de LabVIEW 8. 硬件: Signal Sources (AWG/FG/AO)>>Arbitrary Waveform and Function Generators>>PCI-5402, Signal Sources (AWG/FG/AO)>>Arbitrary Waveform and Function Generators>>PXI-5402 Ambient temperature range of 0 °C to 50 °C. 00. . None. Specifications. Manufacturer: Caterpillar Model: G3516 Power: 660 - 1,300 horsepower available Good condition Caterpillar G3516 Generator Sets available between 1993 and 2008 years. Provides support for NI data acquisition and signal conditioning devices. 1) Use a Frequency List. NI PXI modular systems are ideal for applications like aerospace and defense, automotive, semiconductor, and more. TEL/WeChat:15396237607. Industries. But now I'm looking for a way to generate a much longer constant pulse: I might need the pulse to go high for up to an hour while I run a test. All Manuals. 5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module. , Israel) for voltage output and a relay box (PXI-5402/2569, National Instruments Corp. 2. vi. NI InstrumentStudio 2022 Q1 Readme. The PXI-5406 (Part Number: 779657-01) Waveform Generator comes with unparalleled analog output execution. The idea is to adjust a delay between each of the output. The frequency control word is calculated by dividing the desired output frequency by the sample clock frequency (100MHz for a PXI-5402) and multiplying it by 2^N where 'N' is the width of the DDS accumulator (48 for the PXI-5402). . Control NI-FGEN devices and create your own arbitrary waveforms using MATLAB. The instru ments are from left to right function generator NI PXI-5402, dual channel oscilloscope NI PXI-5112, DC power supply NI PXI-4110 with APS-4100, and DMM NI PXI-4070. Phone: (217) 352-9330. All kinds of module card driver controller servo motor servo motor embedded card wires and cables Power module control module is applicable to steel, hydropower, nuclear power, power generation, glass factory, tire factory, rubber, thermal power, paper making, shipping, navigation, etc ABB — AC 800M controller, Bailey, PM866 controller, IGCT silicon. I've got a PXI-5402 FGen and several PXI-2521 switch blocks in a PXI-1033 chassis. c. . I want to generate a function with a PXI 5402 function gen, and trigger an FPGA acquisition loop each time the function is generated in order to perform repeated measurements on a flexRIO 7962R with the 5752 acquisition module. Jūs iepriekš iegādājāties šo produktu. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。NI™ manufactures arbitrary waveform and function generators that use the NI-FGEN driver. TRS-RenTelco offers a diverse product inventory with solutions for a large variety of applications. . You can also use InstrumentStudio to monitor and control devices being used in external. I don't have a screen shot of the waveform yet but based on what I have seen on other. 00. Part Number(s): 784782-01 |Destinations (PXI trigger lines 0 to 7)18 Polarity Active high (not configurable) Pulse width 230 ns Calibration Interval Recommended calibration interval 1 year Physical Dimensions 3U, one-slot, PXI Express/CompactPCI Express module 2. Do not forget to activate the installed products. Войти РегистрацияNeed to retrieve a quote for your NI products? Use this simple tool to access your online quotes and lock in prices for 30 days. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator —The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. The output voltage of the amplifier was measured by a National Instruments NI-PXI-5122 digitizer. 5 Digit Multimeter Passive Testing Specifications. Each power supply is capable of supplying entire system power, allowing power supply replacement without interrupting system operation. The CH 0 output can be connected to a 50 Ω, ±12 V source without sustaining any damage. See Price. This equipment. Refer to the "Supported Hardware" table in the driver readme file. Learn more about how SCOUT can help maintain the system performance of your PXI Automated Test. 1 V pk-pk to 3. 0 cm × 21. RTSI/PXI Trigger Lines; Trigger Modes. Flexible delivery options, including pick-up and delivery, local drop-off. As it is a A PXI-5412 would be better suited to this task. Use the Ag3446x driver to measure AC voltage from a digital multimeter and output the result. While this is a task that is better suited for our Arbitrary Waveform Generators, perhaps you could use the Fgen Sweep Generator. It looks like NI FGEN 2. † (PXI) Plug the PXI chassis and the calibrator into the same power. The instruments are from left to right function generator NI PXI‐5402, dualchannel oscilloscope NI PXI‐5112, DC power supplyNI PXI‐4110 with APS‐4100, and DMM NI PXI‐4070. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. × 5. Overview. Tektronix DMM157 Multimeter with Cable. used. Trust Trescal for National Instruments PXI-5402 Arbitrary Function Generator Module calibration, maintenance and repair services. Please. $4,900. 00. 2. 12-Slot (8 SCXI Slots, 4 PXI Slots) PXI Chassis —The PXI-1052 is ideal for PXI measurement systems requiring additional signal conditioning such as multiplexing, filtering, isolation, amplification, and switching. The clock frequency needs to change when triggered by events on the FPGA. The PCI-5402 Waveform Generator Device generates the signals with an amplitude of -5 V to +5 V range. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. My function is QA so I don't have direct access to the test equipment but I can request the test engineer collect some data. Using these. 1) NI- PXIe-6535 HSDIO and 2) NI PXI-5402 function generator. Henry . + 2. 0 Kudos Message 1 of 5 (3,294 Views) Reply. A further question wrt PXI-5402 standard function generation. This function generator can generate signals from -5 V to +5 V and uses direct digital. PXIe-6570 Installation 4 3 2 1 1. Celle-ci est connectée à d'autres modules tels que multimètre PXI-4072, générateur de fonctions PXI-5402, oscillo PXIe-5114 et 3 cartes matrices 2811B. A next generation upgrade product has been identified. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. Accepted by. I have only worked with message based instruments so far. NI Product Documentation Center. National Instruments PXI-5402 14-Bit 20 MHz Arbitrary Function Generator. Power down the computer, then the PXI (e) chassis. More information about the Frequency List Mode can be found here. Windows 10 64-bit. 2. NI PXI/PCI-5402/5406 The NI 5402 is a 20 MHz bandwidth,14-bit arbitrary function generator. You can also use InstrumentStudio to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. 0" (on a NI PXIe-1071 module with MAX)? Installing software with MAX and getting it on they module is not the problem, the p. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS). Manuals. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. PXIe, 20 MHz Bandwidth, 1- or 2-Channel, 16-Bit PXI Waveform Generator. zip ‏7439 KB. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. I was working on a basic VI to acquire data using a NI PXI-5402 Function Generator (Ni FGEN) and NI PXI-5105 Digitiser (Ni Scope) I just want the Function Generator to be very basic and generate a 1-5 MHz Sine Wave and the Digitiser should be able to fetch the data continuously and write on to the buffer. hwdb | 1987 +++++- hwdb/20-usb-vendor-model. The NI PXI-5402 (Part Number: 779655-01, 192887E-01L) is a 20 MHz Waveform Generator fit for producing standard functions including sine, square, triangle, ramp, and different signals like psuedorandom noise and DC signals. PXI Express Peripheral Slot 6. This example shows how to generate a sine wave on a function generator using the National Instruments® NI-FGEN driver in simulation mode. Keysight N1021B Differential TDR / TDT Probe 18 GHz. The PXI‑5412 is a 20 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This clock generator can generate signals from -1 V to +1 V and uses direct digital synthesis (DDS) to precisely generate waveforms. Engineers choose NI systems to test faster and more efficiently. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy;Use the Ag3446x driver to measure AC voltage from a digital multimeter and output the result. With a national network of resources, a robust quality program and broad capabilities, we offer standard and custom solutions to deliver fast, accurate calibration when and how it's needed. 2 use in the cryomodules. Waveform Generator 1 Channel PXI-5402 20MHz 3 Years 779657-01 3958561 Data Sheet. I went to the Measurement Studio tab in Visual Studio, and then to. As the frequency control word is an integer. Options I am running into an issue with the PXI-5402 Function Generator card in my system. Pxi 5402 Manual - Manuals Library gives you instant online access to the latest workers compensation information. sbRIO-9632 National Instruments, NI, sbRIO-9632 National Instruments sbRIO-9632 National Instruments Module Clips Drive controller servo motor Contact: Mr. 20 MHz Bandwidth, 1-Channel, 14-Bit PXI Waveform Generator—The PXI‑5402 is a 20 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. You can use MATLAB together with Instrument Control Toolbox as your single software environment to configure, control, and create waveforms with these instruments. 5 V pk-pk into 50 Ω • 0. The PXI‑6542 can sample digital waveforms at up to 100 MHz and interface with common transistor‑to‑transistor logic (TTL) voltage. 2) Create your own waveform using primitive LabVIEW functions, and input that to the FGEN. Consolidate your National Instruments PXI-5402 repair with other instrument service needs to save time, money and hassle. I ran NI MAX, removed the 5402 from the config. i have noticed that the low limits and high lim. Any help is greatly appreciated. You can request. 解決策: NI 5402/5406は、任意波形発生器ではなく、任意関数発生器となりますので、任意の波形を自由に出力することはできません。. . The scope is connected to the other end and sees about a 8 Vpp signal. Use the AgAC6800 driver to make measurements from an AC power supply and output the result. NI PXI-540X ACCESS ACTIVE CH 0 CH 0 REF IN SYNC OUT/ SYNC PFI 0 OUT/ PFI 0 PFI 1 PFl 1 NI PCI-540X Figure 1. また、この波形の周波数や、振幅を変更.